Prior Scientific Single Axis Nanopositioning Titanium Stage

No reviews yet Write a Review
This single axis Nanopositioning stage has one linear axis of motion and is intended primarily for horizontal motion. However, the stage will function in other …

Read more

SKU: QGNPS-X-28C
$15,500.00
Hurry up! Current stock:

This single axis Nanopositioning stage has one linear axis of motion and is intended primarily for horizontal motion. However, the stage will function in other orientations. The capacitive sensor design provides sub-nanometer displacement measurement and closed-loop feedback over a range in excess of 28µm. The millisecond response time and high bandwith make this stage ideal for high-throughput applications. The stage system does not include a controller.

Applications for the NPS-X-28C Nanopositioning stage include atomic force microscopy (AFM), magneto-resistive head and disk drive testing, interferometry, and metrology.

The Nanopostion Stage NPS-X-28C is made to order and the exact specifications of your stage will be provided when you receive it. Typical specifications are as follows:

  • Stage Material: Titanium
  • Open Loop Range: ± 16.5 µm (varies with each stage)
  • Closed Loop Range: ± 14 µm minimum (varies with each stage)
  • Scale factor error (1σ): 0.1% (varies with each stage)
  • Resonant frequency: at 0g load: 5800 Hz is typical, with a minimum of 5300 Hz (varies with each stage)
  • Maximum load: 10 kg for gravity acting in the Z direction
  • Size: 63.5mm L x 42mm W x 15.5mm H
  • Recommended Controller: NPC-D-6110

View the QGNPS-X-28C Datasheet.

NOTE: This item is not returnable.

Prior Part #  QGNPS-X-28C

This product hasn't received any reviews yet. Be the first to review this product!

Description

This single axis Nanopositioning stage has one linear axis of motion and is intended primarily for horizontal motion. However, the stage will function in other orientations. The capacitive sensor design provides sub-nanometer displacement measurement and closed-loop feedback over a range in excess of 28µm. The millisecond response time and high bandwith make this stage ideal for high-throughput applications. The stage system does not include a controller.

Applications for the NPS-X-28C Nanopositioning stage include atomic force microscopy (AFM), magneto-resistive head and disk drive testing, interferometry, and metrology.

The Nanopostion Stage NPS-X-28C is made to order and the exact specifications of your stage will be provided when you receive it. Typical specifications are as follows:

  • Stage Material: Titanium
  • Open Loop Range: ± 16.5 µm (varies with each stage)
  • Closed Loop Range: ± 14 µm minimum (varies with each stage)
  • Scale factor error (1σ): 0.1% (varies with each stage)
  • Resonant frequency: at 0g load: 5800 Hz is typical, with a minimum of 5300 Hz (varies with each stage)
  • Maximum load: 10 kg for gravity acting in the Z direction
  • Size: 63.5mm L x 42mm W x 15.5mm H
  • Recommended Controller: NPC-D-6110

View the QGNPS-X-28C Datasheet.

NOTE: This item is not returnable.